Inverter Connected to Three-Phase Grid – Deye 40-45-50k
Deye 40/45/50K
Product Features
- 4 MPP Trackers, Maximum Efficiency up to 98.7%
- Voltage and Frequency Support Application
- String Smart Monitoring (Optional)
- Wide Output Voltage Range
- Anti-PID Function (Optional)
Model | 40K | 45K | 50K |
---|---|---|---|
Input Side | |||
Max. DC Input Power (kW) | 52 | 58.5 | 65 |
Max. DC Input Voltage (V) | 800 | ||
Start-up DC Input Voltage (V) | 250 | ||
MPPT Operating Range (V) | 200~700 | ||
Max. DC Input Current (A) | 40+40+40+40 | ||
Max. Short Circuit Current (A) | 60+60+60+60 | ||
No.of MPP Trackers | 4 | ||
No.of Strings per MPP Tracker | 4+4+4+4 | ||
Output Side | |||
Rated Output Power (kW) | 40 | 45 | 50 |
Max. Active Power (kW) | 44 | 45 | 50 |
Nominal Output Voltage / Range (V) | 3L/N/PE 127V/220V | 3L/N/PE 133V/230V | |
Rated Grid Frequency (Hz) | 50 / 60 (Optional) | ||
Operating Phase | Three phase | ||
Rated AC Grid Output Current (A) | 100.3 | 112.8 | 125.4 |
Max. AC Output Current (A) | 100.3 | 112.3 | 125.4 |
Output Power Factor | 0.8 leading to 0.8 lagging | ||
Grid Current THD | <3% | ||
DC Injection Current (mA) | <0.5% | ||
Efficiency | |||
Max. Efficiency | 98.7% | ||
Euro Efficiency | 98.3% | ||
MPPT Efficiency | >99% | ||
Protection | |||
DC Reverse-Polarity Protection | Yes | ||
AC Short Circuit Protection | Yes | ||
AC Output Overcurrent Protection | Yes | ||
Output Overvoltage Protection | Yes | ||
Insulation Resistance Protection | Yes | ||
Ground Fault Monitoring | Yes | ||
Anti-islanding Protection | Yes | ||
Temperature Protection | Yes | ||
Integrated DC Switch | Yes | ||
Remote software upload | Yes | ||
Remote change of operating parameters | Yes | ||
Surge protection | DC Type II / AC Type II | ||
General Data | |||
Size (mm) | 700W×575H×297D | ||
Weight (kg) | 60 | ||
Topology | Transformerless | ||
Internal Consumption | <1W (Night) | ||
Running Temperature | -25~65°C, >45°C derating | ||
Ingress Protection | IP65 | ||
Noise Emission (Typical) | ≤55 dB | ||
Cooling Concept | Smart cooling | ||
Max. Operating Altitude Without Derating | 2000m | ||
Warranty | 5 years | ||
Grid Connection Standard | VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/NBR16150 | ||
Operating Surroundings Humidity | 0-100% | ||
Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | ||
Features | |||
DC Connection | MC-4 mateable | ||
AC Connection | IP65 rated plug | ||
Display | LCD 240x160 | ||
Interface | RS485/RS232/Wifi/LAN |